Function of isolation voltage of power supply converter DC module power supply(1)

2024-10-21

AC-DC power module

Regulation of output voltage
For module power products with TRIM or ADJ (adjustable) output pins, the output voltage can be adjusted within a certain range through resistors or potentiometers, and the general adjustment range is ±10%.
For the TRIM output pin, connect the center of the potentiometer to TRIM. In all modules with +S and -S pins, the other two ends are connected to +S and -S respectively. When there is no +S, -S, connect the two ends to the output positive and negative poles of the corresponding main circuit (+S to +Vin, -S to -Vin), and then adjust the potentiometer. The resistance value of the potentiometer is generally more appropriate to use 5 ~ 10kΩ.

power supply converter DC customized non-standard power supply customized module (factory supply are used in different places, and the matching specifications do not need to be selected. For example, AD-DC power supply is isolated. Generally, the isolation breakdown voltage specified in manufacturing sites is 5000VAC to 6000VAC; Generally, the manufacturing sites of dcdc power modules specify 1500VDC to 2500VDC, which will be higher in special manufacturing industries, and 6000VDC is specified in the medical device industry. Zhuo Xuan Electronic Technology is a professional manufacturer of power supply converter DC customized non-standard power supply customized module (factory supply, dcdc power module, acdc customized non-standard power supply customized module (factory supply, high voltage input power module, customized power supply converter DC customized non-standard power supply customized module (factory supply, 3W/10W/25w/75w/100W/200W and other dcdc customized non-standard power supply customized module (factory supply, which can provide a stable and reliable controller voltage for the customer system, and reasonably alleviate the problem of good and bad power use caused by static electricity and surge. It is also a data collection Expected plan for common power of communication subsystem.