Polyurethane has been used in China for a period of time, but due to its high hardness, inconvenient maintenance, and the price reduction of silicone rubber, the cost performance of polyurethane is not high.
(3) Before the installation is completed and the power is turned on, the wiring on each terminal should be checked and checked again to ensure that the input and output, AC and DC, single-phase and multi-phase, positive and negative, voltage and current values are correct. Prevent the occurrence of reverse and wrong connections.
(4) For high-power power supplies, there are generally two or more "+" output terminals and "-" output terminals. In fact, they belong to the same output electrode, but for the convenience of user wiring, they are connected together internally.
(5) The module power supply is not allowed to work at full load for a long time. The utilization rate of linear power supply should be controlled within 60%; the utilization rate of switching power supply should be controlled within 80%, otherwise it may cause early artificial failure of module power supply.
Special attention should be paid to the thermal conductivity related to thermal design. Generally, a thermal conductivity of 0.4W/M•K is defined as high thermal conductivity, and greater than 1 is defined as extremely high thermal conductivity.